Have any Questions?
+ 92 51-4840137
Get in Touch
Have any Questions?+ 92 51-4840137
Follow us

Buraq Integrated Solutions (PVT) LTD

Founded in 2000, Buraq Integrated Solutions (BIS) has successfully executed multidisciplinary projects across Bangladesh, Maldives, Singapore, Thailand, Indonesia, Turkey, UAE, Bahrain, KSA, Australia, and the USA.

Contact Us

Location
HQ: Buraq Integrated Solutions 11-D 6th Road, Satellite Town, Rawalpindi, Pakistan.

STZ: 1st Floor, Alpha-18, NASTP, Old Airport Road, Rawalpindi, Pakistan.

AUS: Buraq Integrated Solutions Unit 55, 10 Yato Road, Prestons NSW 2170, Australia.
Phone
+92 51-4840137
+92 333-5132514
+92 300 5121896
+61 300 786 599
Email
info@buraq.com

Gas Flux & Eddy Covariance

Solutions

Eddy Covariance Measurement System

The Eddy Covariance (EC) system provides high-precision, long-term measurement of exchanges between the atmosphere and biosphere, including CO₂, water vapor, heat, and momentum. A complete setup includes the EC155 closed-path gas analyzer, CSAT3A 3D sonic anemometer, CR6 datalogger, sample pump, and CDM-A116 for sensor expansion. Its compact 5.9 mL sample cell and optimized intake design deliver excellent frequency response (4.3 Hz cutoff) with only 12 W total power consumption, making it ideal for remote and low-power sites.

Automated Gas Flux Processing

The GasFlux CRBasic program enables fully corrected CO₂, H₂O, sensible heat, and momentum flux calculations directly on the datalogger using high-frequency raw data and established scientific correction methods. Tested across diverse environments—such as agricultural fields, open water, forests, and deserts—the system delivers results comparable to traditional PC-based flux processing software.

Benefits & Features

  • New conformal coating protects sonic transducers in harsh or corrosive environments
  • CR6 datalogger offers powerful, expandable processing for mid-level EC systems
  • Ideal for sites with multiple sensors and towers of varying heights
  • Streamlined system architecture simplifies integration and troubleshooting
  • High-quality EC measurements using the EC155 Closed-Path Gas Analyzer and CSAT3A sonic anemometer