Gas Flux & Eddy Covariance

The Eddy Covariance (EC) system provides high-precision, long-term measurement of exchanges between the atmosphere and biosphere, including CO₂, water vapor, heat, and momentum. A complete setup includes the EC155 closed-path gas analyzer, CSAT3A 3D sonic anemometer, CR6 datalogger, sample pump, and CDM-A116 for sensor expansion. Its compact 5.9 mL sample cell and optimized intake design deliver excellent frequency response (4.3 Hz cutoff) with only 12 W total power consumption, making it ideal for remote and low-power sites.

Automated Gas Flux Processing

The GasFlux CRBasic program enables fully corrected CO₂, H₂O, sensible heat, and momentum flux calculations directly on the datalogger using high-frequency raw data and established scientific correction methods. Tested across diverse environments—such as agricultural fields, open water, forests, and deserts—the system delivers results comparable to traditional PC-based flux processing software.

Benefits & Features

  • New conformal coating protects sonic transducers in harsh or corrosive environments
  • CR6 datalogger offers powerful, expandable processing for mid-level EC systems
  • Ideal for sites with multiple sensors and towers of varying heights
  • Streamlined system architecture simplifies integration and troubleshooting
  • High-quality EC measurements using the EC155 Closed-Path Gas Analyzer and CSAT3A sonic anemometer

Specifications

Operating temperature Range -30° to +50°C
Input voltage range 10.5 to 16.0 Vdc
Power

35 W (maximum, at cold startup)

12 W (typical)

System enclosure

Dimensions 54 x 44.5 x 29.7 cm (21.3 x 17.5 x11.7 in.)
Weight

14.6 kg (32.2 lb.) with optional

CDM-A116 module

 13.72 kg (30.25 lb.)

Pump module

Inlet connector 3/8-in. Swagelok
Pressure sensor range 15 to 115 kPa
Pumping speed

3 to 9 LPM (automatically

controlled at the set point,

typically, 7 LPM)