Introduction to Sensor

Measurement and Control Datalogger (CR350)

Compact DataLogger with RS-485

The CR350 is a versatile, ultra-low-power data logger designed for compact measurement and control applications. Engineered for efficiency and reliability, this entry-level device features a powerful instruction set capable of measuring a wide range of hydrological, meteorological, environmental, and industrial sensors. 

Features

Specifications

Temperature Range

  • -40° to +70°C
  • Non-condensing environment

Maximum Scan Rate

10 Hz

Case Material

High-impact-resistant polycarbonate, recycle code 7

Analog Inputs

4 single-ended or 2 differential (individually configured)

Pulse Counters

8 (P_SW, P_LL, C1, C2, and SE1 to SE4)

Voltage Excitation Terminals

2 (VX1, VX2)

Communications Ports

  • USB Type C 2.0
  • RS-232
  • RS-485

Switched 12 Volt

2 terminals

Digital I/O

7 terminals (C1, C2, P_SW, and SE1 to SE4) configurable for digital input and output Includes status high/low, pulse width modulation, external interrupt, and communications functions. Exception: C2 and P_SW don’t do pulse-width modulation.

Analog Input Limits

-100 to +2500 mV

Analog Voltage Accuracy

  • Accuracy specifications do not include sensor or measurement noise.
  • ±(0.04% of measurement + offset) at 0° to 40°C
  • ±(0.1% of measurement + offset) at -40° to +70°C

ADC

24-bit

Charge Terminal Characteristics (CHG+ and CHG-)

  • Input from power converter or solar panel
  • ES1 PS2 energy sources only (Energy Source Class 1 [ES1] and Power Source Class 2 [PS2], as defined in Clauses 5 and 7 of IEC/AS/NZS 62368-1:2022)
  • 16 to 32 Vdc
  • Hold current limit 1.1 A @ 20°C

Battery Terminal Characteristics (BAT+ and BAT-)

  • Input from external battery, 7 Ah lead-acid typical
  • Voltage input 12 Vdc only
  • Hold current limit 3.7 A @ 20°C

Internal Lithium Battery

  • 3 V coin cell CR2032X for battery-backed clock
  • 6-year life with no external power source

Real-Time Clock Accuracy

±3 min. per year

Internet Protocols

Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP(APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, NTP, Telnet, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, MQTT(S)

Communications Protocols

PakBus, PakBus Encryption, Modbus RTU/ASCII/TCP, DNP3, SDI-12, and others

CPU Drive/Programs

50 MB serial flash

Data Storage

50 MB serial flash

Idle Current Drain, Average

0.5 mA (@ 12 Vdc)

Active Current Drain, Average

  • < 1.5 mA (@ 12 Vdc for 1 Hz scan with 1 analog measurement)
  • 8 mA (@ 12 Vdc with processor always on)

Dimensions

16.3 x 8.4 x 5.6 cm (6.4 x 3.3 x 2.2 in.)
Additional clearance required for cables and leads

Weight

288 to 306 g (0.64 to 0.68 lb) depending on communications option selected

CR350-CELL215 Option

-NOTE-The CR350-CELL215 option is intended for use in EMEA countries.
Cell Technologies
  • 2G (GSM/GPRS/EDGE)
  • 3G (UMTS/HSPA+)
  • 4G (LTE CAT-1)
2G Frequency Bands900 and 1800 MHz
3G Frequency Bands850, 900, and 2100 MHz
4G Frequency Bands800, 850, 900, 1800, 2100, and 2600 MHz
Antenna ConnectorSMA (External antenna required; see www.campbellsci.com/order/cr350 for Campbell Scientific antennas)
Power Consumption – Idle14 mA (average)
Power Consumption – Active75 mA (average)
SIM Interface3FF (6 position/contacts)
Supports SIMs that require 1.8 or 3 V
Radio Output Power
  • 23 dBm on LTE
  • 24 dBm on UMTS
  • 27 dBm on EDGE
  • 33 dBm on GSM
Radio Sensitivity Range-99.5 to 110.5 dBm (10 M)
Features

Special Features

01

Dedicated RS-232 / RS-485 Ports

Directly connects to smart sensors, serial devices, and communication modems.
02

Ultra-Low Power Consumption

Designed for long-term remote deployments with minimal current draw.
03

Integrated Surge & ESD Protection

Protects electronics in harsh electrical and outdoor environments.
04

Optional Integrated Radio

Enables wireless networking between remote nodes or gateways.
05

Flexible I/O & Programmability

Allows custom control, automation, and on-board data processing.
06

Event-Driven Alerts & Outputs

Triggers notifications and physical actions based on conditions.
07

Campbell Scientific Reliability

Built for precision, durability, and trusted field performance.
08

Multi-Protocol Support

Compatible with PakBus, Modbus, DNP3, GOES, and other industry standards.
Applications

Primary Applications

Smart Agriculture
Environmental Monitoring
Water Resources
Energy & Utilities
Related Products

Related Products

Measurement and Control Datalogger (CR1000Xe) 

The CR1000Xe Data Logger is a high-performance, research-grade solution designed for precise and reliable data acquisition in demanding applications. It supports a wide range of…..

Datalogger with Ethernet (CR310) 

The CR310 is a cost-effective, compact data logger designed for versatile measurement and control applications. Featuring an integrated 10/100 Ethernet port and…..